How Masonry Buildings Resist Earthquakes Peoria IL

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Peoria are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Peoria Drywall
309.922.0600
PO BOX 3421
PEORIA, IL
LCB Home Improvement & Repair Services
630-284-9026
17 w 320 Oak Lane
Bensenville, IL
Matthews Custom Homes Inc.
630-325-9809
402 1/2 Hudson Ave
Clarendon Hills, IL
v.c.construction.corp
312 388 1244
1727 w albion ave
Chicago, IL
Atop Construction
(773) 884-6100
5525 S Kedvale Av
Chicago, IL
McClanahan Painting, Inc.
(309) 243-2426
7905 W. Robertson
Edwards, IL
Meade Services Inc.
773 761 1595
6400 N Francisco
Chicago, IL
Mr. Handyman,
847-279-0280
251 Milwaukee Avenue, #1011
Buffalo Grove, IL
Chicago Construction Works, Inc.
773-349-6919
1352 N Western Ave
Chicago, IL
Diaz Drywall & Taping
(773) 531-7451
6637 S California Av
Chicago, IL
Data Provided by:
  
Provided By:

How Masonry Buildings Resist Earthquakes

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction